Konica Minolta Honored By The Cannata Report Earns Three Frank Awards Including Best Marketing Strategy, Best Production Print Manufacturer And Best Female Executive 2019.11.6 Konica Minolta Partners With The National Kidney Foundation For NYC Kidney Walk President and CEO Rick Taylor to Co-chair 18th Annual Event. https://omgentrancement.weebly.com/port-royale-2-impero-e-pirati-download-italy-music.html.
The CL-500A is a lightweight, compact illuminance spectrophotometer used for the evaluation of high-class, next-generation lamps such as LED and EL illumination. It is the first handheld illuminance spectrophotometer to conform to both DIN and JIS standards. Hp laserjet 1536dnf mfp user manual pdf. Briggs and stratton model 135232 user manual. The CL-500A can measure illuminance, color temperature, CRI (Color Rendering Index), chromaticity, and spectral power distribution. Plus, the S/P ratio of scotopic illuminance and photopic illuminance can also be displayed.
- Not be removed or the receptor window is scratched, contact the nearest Konica Minolta authorized service facility. In cases of malfunction, do not disassemble the CL-200A or attempt to repair it yourself. Contact the nearest Konica Minolta-authorized service facility. How to Store.
- Konica Minolta's Product User Manuals And Equipment User Guides. Download Or Review Online All Of The Specific Details Across Konica Minolta's Large Selection Of Products And Solutions.
- Konica Minolta's Product User Manuals And Equipment User Guides. Download Or Review Online All Of The Specific Details Across Konica Minolta's Large Selection Of Products And Solutions.
The CL-500A'0019s convenient measurement functions include continuous measurement mode, display of the averaging of multiple measurements, delayed-measurement function, and the display of data at a specific wavelength. The spectral irradiance can be measured at 1-nm pitch from 360 to 780nm, so it can be used for measuring the color of light and photosynthetic photon flux density (PPFD). Vmware dmg support. High speed measurement is possible using the Software Development kit (5 times/second).
The data management software CL-s10w, is included as a standard accessory. It includes a template for expressing the chromaticity variation of illumination light sources such as LEDs or OLEDs in terms of the MacAdam SDCM (Standard Deviation of Color Matching) step. https://droidclever963.weebly.com/spotify-premium-zip-download.html. This allows display of color differences that closely match visual judgment. The software is also equipped with an LED binning function and a spectral irradiance waveform display.
Features
- Portable, lightweight, compact and handheld
- Conforms to both DIN and JIS standards
- High-speed measurement possible using the software development kit
- Can be operated with USB bus power
- Measures and displays both the general color rendering index (Ra) and the special color rendering indexes (R1 to R15)
- Scotopic illuminance and the S/P ratio of scotopic illuminance can be measured with the instrument alone and with the included software
- Measurement functions: Continuous measurement mode, average of multiple measurements, delayed measurement and the display of data at specific wavelengths
- CS-S10w data management software included as a standard accessory
Specifications
Model | Illuminance Spectrophotometer CL-500A |
---|---|
Illuminance meter class | Conforms to requirements for Class AA of JIS C 1609-1: 2006 'illuminance meters Part 1: General measuring instruments'*1 Conforms to DIN5032 Part 7 Class B |
Spectral wavelength range | 360 to 780 nm |
Output wavelength pitch | 1 nm |
Spectral bandwidth | Approx. 10 nm (half bandwidth) |
Wavelength precision | +-0.3 nm (Median wavelengths of 435.8 nm, 546.1 nm, and 585.3 nm*2 as specified in JIS Z 8724)*3 |
Measuring range | 0.1 to 100,000 lx (chromaticity display requires 5 lx or more) |
Accuracy *4, 5 (Standard illuminants A) | Ev (Illuminance) : +-2%+-1 digit of displayed value xy: +-0.0015 (10 to 100,000 lx) xy: +-0.002 (5 to 10 lx) |
Repeatability (2 sigma;) (Standard illuminant A) | Ev: 0.5% + 1digit xy: .0005 (500 to 100,000 lx) xy: .001 (100 to 500 lx) xy: .002 (30 to 100 lx) xy: 0.004 (5 to 30 lx) |
Visible-region relative spectral response characteristics (f) | Within 1.5% of spectral luminous efficiency V ( λ) |
Cosine response (f2) | Ev: Within 3% |
Temperature drift (fT) | Ev: +-3% of displayed value; xy: +-0.003 |
Humidity drift (fH) | Ev: +-3% of displayed value; xy: +-0.003 |
Measurement time | Super Fast mode: Approx. 0.2 sec. (when connected to computer); Fast mode: Approx. 0.5 sec.; Slow mode: Approx. 2.5 sec.; Automatic exposure time setting (high accuracy) mode: Approx. 0.5 to 27 sec. |
Color indication modes | XYZ; X10Y10Z10; Evxy; Ev; Ev; Dominant wavelength, Excitation purity; Correlated color temperature, Delta;uv; General color-rendering index (Ra); Special color-rendering indexes (Ri (i=1~15)); Spectral graph; Peak wavelength; Delta(XYZ);Delta(X10Y10Z10);Delta (Evxy);Delta (Ev); Rank display; Scotopic illuminance; S/P ratio; Spectral irradiance |
Other functions | Data memory: 100 data; User calibration function (when connected to computer); Averaged measurements; Delayed Measurment; Continuous measurement; Auto power off function |
Display languages | English, Japanese, Chinese (Simplified) |
Interface | USB 2.0 |
Power source | Rechargeable internal lithium-ion battery (Operating time per charge: Approx. 6 hours when new); AC adapter; USB power bus |
Operating temperature/humidity range | -10 to 40°C, relative humidity of 85% or less (at 35°C) with no condensation |
Storage temperature/humidity rangen | -10 to 40° C, relative humidity 85% or less (at 35° C) with no condensation |
Dimensions (W x H x D) | 70 x 165 x 83 mm |
Weight | 350 g |
*1 For Section 7.6.3 Response Time, when measurement speed mode is set to FAST mode. | |
*2 For 585.3 nm, evaluation performed using substitute wavelength of 587.5 nm. | |
*3 Based on Konica Minolta test standards (change in temperature of 2 deg;C or less after zero calibration.) | |
*4 Automatic exposure time setting (high accuracy) mode |
Included Accessories
FD-A05 Soft Case
Buy Now >
Lens Cap with Strap
Buy Now >
Minolta Cl-200a
Suggested Accessories
JCSS and Cal. Cert. Set A
Buy Now >
Test Report (Acceptance Angle)
Buy Now >
![Manual Manual](/uploads/1/3/3/2/133282159/664205687.jpg)
Konica Minolta Cl 200 User Manual Pdf
Model | CS-200 Luminance Color Meter |
---|---|
Measurement range | 0.01 - 200,000 cd/m² (Measuring angle 1 °) 0.01 - 5,000,000 cd/m² (Measuring angle 0.2 °) 0.01 - 20,000,000 cd/m² (Measuring angle 0.1 °) |
Accuracy (Measuring angle 1°) *1 (Standard Illuminant A; Temperature: 23 degC+-2 degC, Relative humidity: 65% max.) |
150 cd/m² ( for Illuminant A ) : Lv +-2 % +-1digit ; xy +-0.002 0.01-0.5 cd/m² ( for Illuminant A ) : Lv +-0.02cd/m² +-1digit ; 0.5-1 cd/m² ( for Illuminant A ) : Lv +-0.02 cd/m² +-1digit ; xy +-0.007 1-10 cd/m² ( for Illuminant A ) : Lv +-2 % +-1digit ; xy +-0.004 10-200,000 cd/m² ( for Illuminant A) : Lv +-2 % +-1digit ; xy +-0.003 5000 cd/m² ( for Illuminant A ) : color filter (R, G, B) ; xy +-0.006 Light source at 5000 cd/m² + color filter (R, G, B) |
Repeatability (Measuring angle 1°) *2 (Standard Illuminant A) | 0.01-1 cd/m² ( for Illuminant A ) : Lv +-0.01 cd/m² +-1digit ; --- (2σ/Auto) 1-2 cd/m² ( for Illuminant A ) : Lv +-0.5 % +-1digit ; xy 0.002 (2σ/Auto) 2-4 cd/m² ( for Illuminant A ) : Lv +-0.5 % +-1digit ; xy 0.001 (2σ/Auto) xy +-0.007 4-8 cd/m² ( for Illuminant A ) : Lv +-0.5 % +-1digit ; xy 0.0005 (2σ/Auto) xy +-0.004 8-200,000 cd/m² ( for Illuminant A ) : Lv +-0.1% +-1digit ; xy 0.0004 ((2σ/Auto) xy +-0.003 |
Measurement time | Automatic setting between 1s and 60s (AUTO); Automatic setting to 1s or 3s (LTD. AUTO) 0.5 sec / meas. (Super-FAST) 1 sec / meas.(FAST)3 sec / meas. (SLOW) 12 sec / meas. (Super-SLOW) |
Measurement method | Spectral method, Grating + linear photo diode array |
Measuring angle | 1°, 0.2°, 0.1°(switchable) |
Minimum measuring area | 0.5 mm 0.1 mm (close up lens) |
Minimum measuring distance | 296 mm (Distance from front edge of metal lens barrel) |
Observer | 2/10° |
Color space | Lv x y, Lv u' v', Lv T Delta;uv, XYZ, dominant wavelength |
Measurement synchronization setting range | Vertical synchronization frequency : 40.00 to 200.00Hz |
Interface | USB 1.1 |
Power source | AC adapter or 4 AA-Size Batteries |
Battery life | Approx. 3 hours (continuous measurement / Fast mode / AA-size alkaline cells) |
Size | 95 mm (W) x 127 mm (H) x 330 mm (L) |
Weight | 1.8 kg (without battery) |
Operating temperature/humidity range | 0°C to 40°, relative humidity 85% or less (at 35°) with no condensation |
Storage temperature /humidity range | 0°Cto 45°C,relative humidity 85% or less (at 35°C)with no condensation |
*1 23°C+-2°C Lv = 0.01-10 cd/m², SLOW, average of 30 measurements Lv = 10 cd/m² and higher, SLOW, average of 10 measurements | |
*2 At 0.2°measuring angle, the amount of received light is approx. 1/25 of that for 1°. Therefore, the repeatability becomes the same as that for 1 degwith 25 times lower luminance. At 0.1°measuring angle, the amount of received light is approx. 1/100 of that for 1°. Therefore, the repeatability becomes the same as that for 1 degwith 100 times lower luminance. |