User Manual
Page 1 Radical-7 Operator's Manual. Page 3 The Radical-7 operating instructions provide the necessary information for proper operation of all models of the Radical-7 Pulse CO-Oximeter system. There may be information provided in this manual that is not relevant for your system. Garmin nuvi 52lm user manual pdf. Masimo Radical Pulse Oximeter User Manual Pulse Oximeters, Manuals, 12262 Masimo Operator's Manual, Rad-9, 12262 Radical Signal Extraction Pulse Oximeter Service Manual UM i The. Featuring “gold standard” Masimo SET® pulse oximetry, proven in more than 100 The Radical-7 features a bright multi-color or monochromatic screen.
Rank arena portable dvd player user manual. The Masimo Radical-7 Service Manual (#13928) is intended to provide the necessary information for proper servicing of all models of the Radical-7 Pulse Oximetry and CO-Oximetry systems. The Radical Operating Instructions are intended to provide the necessary information for proper operation of all models of the Radical pulse oximetry system.There may be information provided in this manual that is not relevant for your system. General knowledge of pulse oximetry and an understanding of the features and functions of the. User manual instruction guide for RAD7CA RAD7CA Masimo Corporation. Setup instructions, pairing guide, and how to reset.
DESCRIPTION
The Radical-7 leverages Masimo's noninvasive measurements with functionality designed to automate the process of care and enable clinicians to adapt to changing monitoring needs in individual patients and care areas.
Choose the noninvasive measurements that are right for your clinical setting—oxygen saturation, pulse rate, and perfusion index in addition to total hemoglobin, total arterial oxygen content, pleth variability index, carboxyhemoglobin, methemoglobin, and acoustic respiration rate.
Choose the noninvasive measurements that are right for your clinical setting—oxygen saturation, pulse rate, and perfusion index in addition to total hemoglobin, total arterial oxygen content, pleth variability index, carboxyhemoglobin, methemoglobin, and acoustic respiration rate.
FORUMSView All (10)
Ask a New Question1Reply7 months ago | 7 months agoHard Reset I have found that many miscellaneous issues such as touchscreen problems can be resolved by performing a hard reset on this device. This is performed by pushing the power button once. Wait for the Masimo logo to appear, then press and hold the power button again. Continue holding the power button until you hear a double beep and then release. Reply |
-rcderek22 2 years ago | 2 years agoService watchdog One of our Radical 7's is showing a Service watchdog error then unsuccessfully attempts to power itself off. Has anybody else seen that? Is there any way to repair these without sending them in? Thanks-DerekReply |
0Replies2 years ago | 2 years agoSetting output to ASCII-2 for download data On my Radical 7 the output selection format in Data output menu has only one choice, 'Data collection' (that, by the way, I don't understand). To download data with the TrendCome program, i need to set this to ASCII-2, but I can't.Any hint?Reply |
Masimo Radical 7 Cable
DOCUMENTS / MANUALSView All
FEATURES
- Intuitive Operation - Quick touch, drag, and drop. Clinicians can move any parameter to and from center and bottom of the display, never losing track of any vital signs
- Adaptable Functionality - Standalone device; Detachable, battery-operated wireless device; Handheld or wearable
- Integrated Wireless Connectivity - Keeps patients connected even while they are ambulating to enable clinician notification and automate charting and enable meaningful use of electronic health record systems
- Powerful Clinical Applications - Operating Room, PACU, ICU, Medical-Surgical Care, Neonatal Intensive Care, Newborn Screening, Emergency and Respiratory Care
SPECIFICATIONS
Instruction Manual
Memory | 72 hr |
Operating Life | 10 hr |
Pulse Rate Range | 25-240 BPM |
SpO2 Range | 0-100% |
Weight | 1.2 lbs |